1. Start with net irrigation depth
Net irrigation depth is the water you intend to add to the root zone during one irrigation event. It depends on the crop, growth stage, soil moisture and effective rainfall. Here, 10 mm is a worked assumption rather than an irrigation recommendation.
Over 2.5 ha: 2.5 × 10 × 10 = 250 m³ net. One millimetre of water over one hectare equals 10 m³.
2. Convert to gross volume
Divide net volume by efficiency expressed as a fraction. If conveyance losses are separate from field application losses, multiply the two efficiencies to estimate the volume needed farther upstream.
At 80% efficiency for the point being assessed: 250 ÷ 0.80 = 312.5 m³ gross.
3. Check the available pumping window
Divide gross volume by the pumping hours actually available, excluding expected interruptions. At a constant flow, calculate pumping time the other way around: gross volume ÷ flow.
To deliver 312.5 m³ in 8 hours, allow approximately 39.1 m³/h at the point being assessed.
| Assumed flow | Estimated time | Within an 8-hour window? |
|---|---|---|
| 25 m³/h | 12.5 h | No |
| 40 m³/h | 7.8 h | Yes, based on time alone |
What to check before choosing a pump
- The water source: sustainable borehole yield or available reservoir volume.
- Total dynamic head: elevation, pumping water level, required pressure and friction losses.
- The operating point on the pump curve and the zones that will run together.
- For solar pumping, the volume the system can deliver over the day, rather than an assumed constant rated flow.
This calculation is for comparing scenarios. It does not determine the crop irrigation dose or select a pump.